Skip to content

Completed project · Ealing, West London

Chimney Breast Removal in Ealing Complete removal, professionally made good.

Complete chimney breast and chimney stack removal in a 1930s semi-detached house, carried out with structural engineer input and Building Control approval. The chimney was removed throughout and the affected areas were made good within five working days.

Completed chimney breast removal and making-good work in a 1930s semi-detached house in Ealing Completed Ealing chimney removal
1930s Semi-detached house
Complete Stack and chimney breast removal
Approved Engineer and Building Control
5 days Including making good
£4,100 Confirmed project cost, excl. VAT

Project overview

Complete removal through the house

Growchance completed the full removal of the chimney stack and internal chimney breast from this 1930s semi-detached house in Ealing, West London.

The project was planned with input from a structural engineer and completed with Building Control involvement. The chimney was not shared with the neighbouring property, allowing the complete structure to be removed rather than leaving retained masonry that required permanent support.

Removal and making-good work were completed within five working days. The confirmed project cost was £4,100 excluding VAT for the agreed scope of this individual project.

Chimney breast in a 1930s semi-detached house in Ealing before removal
Before chimney removal

Agreed project scope

Removal, approval and making good

The work was coordinated as one defined structural alteration, from the initial engineering requirements through to removal and the repair of the affected internal areas.

  • Structural engineer input before demolition
  • Building Control involvement
  • Complete chimney stack and breast removal
  • Making good to the affected areas
  • Five-working-day project programme
Property
1930s semi-detached
Chimney arrangement
Not shared
Completion period
5 working days
Confirmed cost
£4,100 excl. VAT

Before the work

The existing chimney arrangement

The agreed scope covered the complete chimney structure belonging to this 1930s semi-detached house, including the external stack and the internal chimney breast below.

The chimney was not shared with the adjoining property. This meant the project could be planned as a complete removal rather than a partial alteration that left retained chimney masonry requiring permanent support.

Before demolition began, the existing arrangement and removal sequence were considered alongside the structural engineer’s requirements and the Building Control process.

Exterior of the 1930s semi-detached house in Ealing showing the chimney stack before removal
Existing chimney stack
Internal chimney breast in the Ealing house before removal
Internal chimney breast

Existing arrangement

One complete chimney within the property

Because the chimney was not shared, the external and internal sections could be treated as one coordinated removal sequence.

  • External chimney stack included in the removal scope
  • Internal chimney breast removed completely
  • No neighbouring chimney masonry formed part of the structure
  • Affected areas included within the making-good scope

Before demolition

Engineering, approval and the removal sequence

The chimney was not removed as an isolated demolition task. Structural engineer involvement and the Building Control process formed part of the project before the complete removal was carried out.

It was also confirmed that the chimney was not shared with the adjoining property. The work could therefore be organised around removing the complete stack and internal chimney breast rather than retaining an upper section of masonry within the house.

Confirmed

Structural engineer involvement

A structural engineer was involved before the chimney removal proceeded, allowing the work to follow the requirements established for this particular house and chimney arrangement.

Confirmed

Building Control involvement

Building Control formed part of the project process, providing the required oversight for the structural alteration and the completed work.

Property checked

The chimney was not shared

The chimney belonged to the Ealing property rather than forming part of a shared stack with the neighbouring house. This was an important confirmed fact when defining the removal scope.

Agreed scope

Complete removal was planned

The agreed project removed the external chimney stack and the internal chimney breast completely, followed by making good to the areas opened during the work.

Project result

Confirmed cost, programme and completed scope

The complete chimney removal and agreed making-good work were completed in five working days for a confirmed project cost of £4,100 excluding VAT.

This was the final confirmed figure for this individual Ealing project. It reflected the arrangement of this particular non-shared chimney, the requirements of the 1930s semi-detached house and the agreed construction scope.

The figure should not be treated as a standard package price for every chimney removal. Property type, access, retained masonry, engineering requirements, approvals and the extent of making good can all affect the final quotation.

Confirmed Ealing project cost

£4,100 Excluding VAT

The confirmed cost relates to the agreed chimney-removal and making-good scope completed at this individual Ealing property.

Programme
5 working days Including the agreed making-good work.
Removal scope
Complete Chimney stack and internal chimney breast removed.
Engineering
Involved Structural engineer input formed part of the project.
Building Control
Approved The structural alteration followed the approval process.

What the result covered

One complete structural-alteration project

The confirmed outcome combined the removal itself with the professional and approval requirements established for the property, followed by making good to the affected areas.

  • Structural engineer involvement
  • Building Control approval
  • Complete chimney removal
  • Making good included

Start your chimney removal project

Tell us about your property and the chimney you want to remove.

Share a few details about the chimney breast, stack or complete chimney removal you are considering. We will review your enquiry and contact you to discuss the property, structural assessment, likely approvals and whether a site visit is appropriate.

Helpful details

London postcode, property type, floors affected and whether you are considering partial or complete chimney removal.

Project information

Mention if the chimney may be shared and whether you have photographs, plans, structural drawings or Building Control information available.

Submitting an enquiry does not create a contract or guarantee availability. Project suitability and the appropriate scope are confirmed after discussion and assessment.

Request Your Free Site Visit